Nycote 7-11 Dark Blue
Nycote® 7-11 Dark Blue provides excellent high impact, abrasion resistance, flexibility, and toughness at temperatures of -70°F to +400°F (-57°C to +149°C). Apply Nycote® 7-11 Dark Blue to substrates that need protection from corrosion, electrical conduction and friction. This liquid formula can be easily applied by painting, spraying or dipping areas that need protection from aircraft fuels, oil, lubricants, phosphate ester hydraulic fluids, salt spray and water.
/Product%20Page%20Assets/711_DarkBlue.webp?width=375&height=375&name=711_DarkBlue.webp)
Certified to Perform
Nycote® 7-11 Dark Blue was designed for EMBRAER Aircraft to specifically to meet their stringent requirements.
Nycote® Dark Blue is used to protect and secure electrical connection installations, fasteners, and numerous other potentially moist areas in all aircraft at the EMBRAER manufacturing site located in São Paulo Brazil.
Nycote 7-11 Dark Blue meets the standards for outgassing per ECSS-Q-ST-70-02.
Nycote 7-11 Dark Blue meets ISO 22196 International Organization for Standardization Method 22196 – The measurement of antibacterial activity on plastics and other non-porous surfaces.
Product Details
Product Specifications
+| Physical Properties: Temperature Range from -70°F to +300°F (-57°C to 149°C) | ||
|---|---|---|
| Physical Properties | Resin | Film |
| Viscosity: @ 72°F Zahn #2 Cup | 50-90 Seconds | N/A |
| Solids Content (non-vol.) | 19% | N/A |
| Flash Point: C.O.C | 70°F | N/A |
| Shelf Life @ 75°F | Six Months | N/A |
| Film Thickness, 1 Dipcoat | N/A | 0.5 mil |
| Coverage Per Gallon | 300 sq. ft. | N/A |
| Tack-Free Time, 50% RH @ 70°F | N/A | One Hour |
| Film Pencil Hardness | N/A | 1-H |
| Adhesion ASTM D4541-09 (pull-off stress) | N/A | 1200 p.s.i. at temperaturesof -70°F to +400°F (-57°C to +149°C) |
| Abrasion Resistance – (500 Gr. #17 wheel 100 cycles) | N/A | 3.0 mgm |
| Adhesion to ASTM D3359-5B | - | 0% affected at180 pull |
| Scratch Hardness – 1000G Load | - | - |
| Airbus Fuel Resistance to ISO 1817 – No separation or cracks of ID Labels | - | Pass |
| Color shade to ASTM 4471 & Airbus spec(DAN1172/1174) Transparent liquids | - | Pass |
| Sheer Strength | - | > 3.9 |
| Elongation Break | - | > 200 |
| Heat Force Cure * Always check with your own internal engineering department to ensure materials you intend to force cure can withstand the temperatures listed on the Nycote table | - | 2-HR |
| ASTM 2832 – Solids Content Non-volatile | - | Pass |
| UVB @300 hours Resistant to ASTMG154-No degradation of the coating /Nylon will yellow slightly over time | - | Pass |
| Evaluation of ASTM D5264 standard Sutherland Rub testing to gauge the amount of scuffing or abrasion caused during shipping, handling, and storage. TEST REPORT: SN 2206163 Rev. 01 | - | - |
Fluid Resistance
+| Fluid Resistance – 30 days immersion @ 75°F | |
|---|---|
| JP-4 | Excellent |
| JP-5 | Excellent |
| JP-8 | Excellent |
| JP-10 | Excellent |
| Kerosene | Excellent |
| Gasoline | Excellent |
| Skydrol® | Excellent |
| 100% RH @120°F | Excellent |
| Distilled Water | Excellent |
| Tap Water | Excellent |
| Salt Spray | Excellent |
| 80% JP-4 Bacteria Laden Distilled Water | Excellent |
| H2O Immersion Composite (Submersed 7 days)** | Excellent |
| H2O Immersion Metal** | Excellent |
| Potassium Formate Submersion 24-hours | Excellent |
| Potassium Acetate Submersion 24-hours | Excellent |
Adhesion Characteristics
+| Untreated Aluminum | Excellent |
| Chem-filmed (Irridited) Aluminum | Excellent |
| Anodized Aluminum | Excellent |
| Stainless Steel | Excellent |
| Fiberglass | Excellent |
| Zinc Chromate Primed Aluminum | Excellent |
| Any Metal Surface | Excellent |
| Adhesion SAE-AMS-S-4383 and MCS9001C | Excellent |
| Glass | Excellent |
| Carbon Composites / Tin / Vinyl | Excellent |
| PTFE / Viton / TPU | Excellent |
| Adhesion measuring by adhesion tape testJAW ISO 2409 Dry Test Classification(0 indicates best performance on a scale f 0-3)** | Result 0 |
Special Properties
+| ECSS-Q-ST-70-02 Outgassing | Compliant (RML < 1,00%, CVCM< 0,10%) |
| Fungus Testing ASTM G21 | |
| HCV-Virucidal efficacy of treated or impregnated surface | |
| ISO22196 Coating efficacy to microorganisms S. Aureus ACCT6538 & E. Coli ACCT9739.Effectively kills microbes. | 99.99003% Kill |
| Permeation Testing to: | MIL-DTL-5578D Aircraft Fuel Tanks Self Sealing;MIL-DTL-27422F Fuel Tank Crash & Ballistic Resistance;MIL-T-52983G Fuel Tanks Fabric Collapsible |
| ECSS-Q-ST-70-02 Outgassing compliant (RML < 1,00%, CVCM< 0,10%)Fungus Testing ASTM G21 HCV-Virucidal efficacy of treated or impregnated surface ISO22196 Coating efficacy to microorganisms S. Aureus ACCT6538 & E. Coli ACCT9739.Effectively kills microbes. 99.99003% KillPermeation Testing to: MIL-DTL-5578D Aircraft Fuel Tanks Self Sealing;MIL-DTL-27422F Fuel Tank Crash & Ballistic Resistance;MIL-T-52983G Fuel Tanks Fabric CollapsibleIPC-CC-830C – Qualification and Performance of Electrical Insulating Compound for Printed Wiring Assemblies | Insulating Compound for Printed Wiring AssembliesMeets Florescent IPC-CC-830C–MATERIALS/CURE/ FLUORESCENCE/APPEARANCEIPC-CC-830C– paragraphs 3.5.1 ASTM D1084 – Standard Test Methods for Viscosity of AdhesivesIPC-CC-830C– paragraphs 3.3.2 – Shelf-lifeIPC-CC-830C– paragraphs 3.5.5 IPC-TM-650 Method 2.4.5.1 – FlexibilityIPC-CC-830C– paragraphs 3.5.6UL 94 HB – FlammabilityIPC-CC-830C– paragraphs 3.6.1 IPC-TM-650 Method 2.5.7.1 – Dielectric withstanding voltageIPC-TM-650 method 2.6.3.4A – Moisture and insulation resistanceIPC-CC-830C para. 3.7.2 IPC-TM-650 method 2.6.7.1 – Thermal shockIPC-TM-650 method 2.6.3.7 – Hydrolytic Stability |
NSNs
+- 8010-01-565-3597, 8010-01-134-0415, 8010-01-584-8587
Storage Temperature Requirements
+- Store at 70°F (21°C). Keep away from fire or flame.
- Note: Ideal storage temperature is 70°F (21°C); acceptable storage range is between 65°F to 80°F (18.3°C to 26.7°C). Storing below 65°F (18.3°C) may cause cloudiness or gel; heat at 180°F (82°C) for two hours. This should restore the product to its normal liquid condition. If possible, re-verify viscosity with Zahn #2 cup (50-90 seconds).
- Nycote® 7-11 Dark Blue has a six-month shelf life. The container can be opened, applied and then re-sealed for a period of six months. The storage temperature should be maintained for the entire shelf life period. The container must always be stored in an upright position. If the storage temperature is not the ideal, nor within the acceptable range, the result may change the nature of the Nycote®product, as well as, causing cloudiness of the liquid. At all times, the product should be kept from freezing.
Cure Time Table
+Allow one to two hours to become tack free. In dry air allow 72 hours at room temperature for full cure or:
- Heat twelve hours @ 120°F (49°C)
- Heat eight hours @ 150°F (66°C)
- Heat four hours @ 180°F (82°C)
- Heat two hours @ 220°F (105°C)
- Cure film temperature range is -70°F to +400°F (-57°C to 204°C)
OEM Product Specifications / ASTM Testing Standards
+OEM/Specs:
- BS7225
- DMS1850
- DWG55135
- ESE RPT-7456-015
- FED-STD-141
- MC5014
- MC9014
- MIL-DTL-27422F
- MIL-DTL-5578D
- MIL-H-5606
- MIL-I-46058
- MIL-T-52983G
- NAS1611
- NAS1613
- PCS5157
- SAE-AMS-22725
- SAE-AMS-S-4383
- SAE AMS-S-8802
- MEP 10-057G
- BAC 5157
- Airbus CML 07-001B, 16-503
- PPS 9.06 – Electrical bonding and ground of aircraft structures
Standards:
- ASTM D445
- ASTM D1084
- ASTM D-1400
- ASTM D-1475
- ASTM 2832
- ASTM-B117-11
- ASTM D-1310
- ASTM D4060
- ASTM D471
- ASTM D7901
- IPC-TM-650
- ISO-1817
- ISO-9116
- Method 6192
- ECSS-Q-ST-70-02 Outgassing for space applications
- ISO22196 effective against bacteria
- ASTM G21 anti-fungus
- IPC-CC-830C electrical insulation conformal coating for electronics